    Cabinet Type CT PT Test Equipment System Error Measurement


    Cabinet Type CT PT Test Bench System MCHZDZ-3Z


    System Configuration


    1) HZDT Fully automatic Cabinet type Control Bench

    2) Digital Transformer Tester

    3) Current Transformer Burden (5A/1A optional)

    4) Standard Current Transformer ( with Current Source)

    5) Voltage Transformer Burden

    6) Standard Voltage Transformer ( with Voltage Source)

    7) Current Transformer Primary Testing Cable

    8) CT & PT Secondary Testing Cable

    9) PC Test software


    Main Function

    Ratio error and phase angle error test of CT & PT


    Technical Parameter & Features

    HES-10 CT&PT Test Bench

    Input VoltageAC 220+/-10% 50HZ+/-0.5hz
    Output voltageAC 0-250V
    Rated Capacity25KVA
    “Open-circuit demagnetization”, “Closed-circuit demagnetization”, “Error measurement”
    Over current protection:>100A
    FY current transformer burden,FY voltage transformer burden,HES-1C Digital Transformer Tester,Other Control function etc

    Digital Transformer Tester

    Voltage Range150V, 100V, 100/√3V (customization available)
    Current range5A, 5A(S), 1A, 0.5A
    Accuracy class2.0
    Ratio error±0.0001% ~ ±19.99%
    Phase error±0.01' ~ ±900'
    Impedance0.001Ω~ 19.99Ω. Minimum resolution: 0.001Ω
    Admittance0.001 ms ~ 19.99ms. Minimum resolution:0.001 ms
    Rated frequency50 or 60HZ

    Standard Current Transformer with current generator

    Rated primary current(A)5-5000A
    Rated secondary current5A or 1A
    Accuracy class0.02%, 0.05%, 0.05S%, 0.01%, 0.005% (optional)
    Rated secondary load0.2 ohm
    Frequency50HZ
    Operating Range1%--120%
    Capacity of Current Source25kVA or more

    Fully automatic Current transformer burden box

    Rated Current5A, 1A
    Operating Range1%--120%
    Rated load (VA)2.5VA-60VA (customization is available)
    Rate Frequency50Hz or 60HZ
    Accuracy Class±3%
    Power factor0.8, 1.0
    Full automatic, three phases can be tested at the same

    Fully automatic Voltage transformer burden box

    Rated voltage100V, 100/√3V or more options
    Operation Range20%--120%
    Rated load1.25VA-80VA (customization is available)
    Fundamental error±3%
    Power factor0.8, 1.0
    Rated Frequency50Hz or 60Hz

    Standard Voltage Transformer with Voltage Generator


    Rated primary voltage6kV,10kV,15kV,22kV,35kV or more option
    Rated secondary voltage100V,100/√3V,110V,110/√3V, or more option
    Accuracy class0.05% or higher accuracy class
    Secondary capacity0.5VA or more option
    Power factorcosΦ=1.0