    Phase Angle Error CT PT Test Set


    Digital Transformer Tester HEWE series CT PT Test Equipment Comparator


    Technical Parameter

    Accuracy class2
    Current range5A, 1A
    Voltage range100V,100/√3V
    Percentage ErrorLess than 1.5%*FS
    Basic Error
    When testing CT PT error & impedance & admittance, the error will not beyond:

    ΔX=±(X*2%+Y*2%+Dx)

    ΔY=±(X*2%+Y*2%+Dy)

    ΔX: basic error limit value of in-phase component

    ΔY: basic error limit value of Quadrature Component

    X: Indication absolute value of in-phase component

    Y: Indication absolute value of Quadrature Component

    Dx & Dy: Zero error and Quantizing Error

    When testing CT & PT, Dx,Dy=1(or 2)%*(Error limit value of CT & PT

    When testing Z & Y, Dx,Dy= 3 digits


    Measure Range & Resolution

    CT PT classTest RangeResolution
    In-phase componentQuadrature ComponentIn-phase componentQuadrature Component
    0.01±0.4000±13.7520.0001%0.001'
    0.02
    0.05
    0.1±4.000±137.520.001%0.01'
    0.2
    0.5
    1.0±40.00±999.90.01%0.1'
    Impedance Measure Range & Resolution
    RangeMeasure Range (Ω)Resolution
    5A±1.0000.0001
    1A±6.0000.0001
    Admittance Measure Range & Resolution
    RangeMeasure Range (mS)Resolution
    100V±9.99990.0001
    57.7V±9.99990.0001

    Features


    1) LCD display

    2) Test of ratio, ratio error, phase angle error, impedance, admittance

    3) Test data values are all displayed

    4) Used for testing of class 1 to 0.01 instrument transformer with rated current 5A and 1A,

    rated voltage 100V, 100V√3V

    5) Display ratio error & phase angle error of all test points under rated burden or lower limit

    burden 1%-120% Rated current or 20%-120% rated voltage