    0.02 Class CT PT Test Equipment , Low Current CT Test Kit


    0.02 Class 60A CT PT Test Equipment Low Current CT Test System


    System Configuration

    Low-Current CT Tester

    Two-Stage Standard Current Transformer

    CT Test Power source


    Technical Parameter


    Low-Current CT Tester (Bridge)

    Display:LED
    Measure item:Ratio errors & Phase errors of the low-Current CT
    Rated current:1mA, 2mA, 5mA, 20mA, 50mA
    Multiplier:0.5, 1, 1.5, 2, 3
    Accuracy class:±2%
    Operation range:(1%-200%).In
    Frequency:50/60Hz
    Ratio error range:±0.0001% ~ ±19.99%(Three positions: 1.999‰, 19.99‰, 199.9‰)
    Minimum resolution:0.0001%.
    Phase error range:0.01' ~ ±900'(three positions: 9.00', 90.0', 900')
    Minimum resolution: 0.01'
    Alarm Function:Provided the sound & light alarm function when the polarity abnormal or ratio inconsistent.
    Provided load for object CT:0Ω, 5Ω, 10Ω, 20Ω, 30Ω, 50Ω, 100Ω, 200Ω, 250Ω, 500Ω (COSφ=1.0)
    Input load on standard side:10Ω (COSφ=1.0)
    Communication Interface:Provided the RS232 serial communication interface
    Power supply:AC 220V±10%
    Power consumption:< 20VA

    Two-Satge Standard Current Transformer

    Frequency:50Hz/60Hz
    Primary Current (A):0.6,1,1.5,2.5,3,4,5,6,7.5,8,10,15,20,30,50,60
    Secondary Current (mA):1, 1.5,2,2.5,3,10/3,4,5,20/3,7.5,8,10,15,50/3,20,25,30,100/3,50
    Rated Current Ratio:Arbitrary combination of Pri,Current and Sec.Current
    Accuracy Class:0.02%
    Operation Range:(5%-300%).In
    Secondary Burden:10Ω
    Power Factor:COSΦ=1.0
    Voltage Level:AC 600V
    Insulation:Air
    Operating Condition:Temperature: -5 oC ~ +40 oC
    Relative Humidity (RH): up to 85% (max 90%)
    Dimension (mm) :460x380x160
    Weight ( kg ):~15kgs

    CT Test Power Source

    Input Voltage:AC 220V±10% 50/60Hz
    Output Current:AC 5A, 50A, 100A
    Rated Capacity:~500VA
    Output Voltage:Provided the Coarse adjustment & Fine adjustment
    Adjustment Model:Manual adjustment

    Feature

    1) high accuracy and stability

    2) specially used for test of low current CT

    3) small size and weight, suitable for carrying

    4) operation mode: manual

    5) ratio error test, phase angle test, polarity test


    Optional design for bridge