    0.05% CT PT Test Equipment Phase Angle Error Measurement

    0.05% Standard Bench Type CT PT Test Equipment Test Bench HES-10

    System Configuration:


    1) HES-10 CT&PT Test Bench

    2) HES-1C Digital Transformer Tester

    3) FY49 Current Transformer Burden (5A/1A optional)

    4) HLS-30G2 Standard Current Transformer ( with Current Source)

    5) FY95 Voltage Transformer Burden (100V,100/√3V or other ratio requirements are available)

    6) HJS-35G2 Standard Voltage Transformer ( with Voltage Source)

    7) Current Transformer Primary Testing Cable

    8) CT & PT Secondary Testing Cable

    9) PC Test software


    Main Function

    Ratio error and phase angle error test of CT & PT


    Technical Parameter & Features

    HES-10 CT&PT Test Bench

    Input VoltageAC 220+/-10% 50HZ, Single Phase
    Output voltageAC 0-250V
    Rated Capacity10KVA
    Adjustment methodManual, coarse & fine adjustment
    “Open-circuit demagnetization”, “Closed-circuit demagnetization”, “Error measurement”
    Over current protection
    Equipment Can be installation and placed: FY current transformer burden,FY voltage transformer burden,HES-1C Digital Transformer Tester,Other Control function etc

    HES-1C Digital Transformer Tester

    Rated current &voltage5A, 1A, 110V, 110/√3V, 100/√3V, 100/3V etc
    Measuring Range
    Ratio error±0.0001% ~ ±19.99%(three positions: 0.1999%, 1.999%, 19.99%). Minimum resolution:0.0001%.
    Phase error±0.01' ~ ±900'(three positions: 9.00',90.0',900'). Minimum resolution: 0.01'
    Impedance0.001Ω~ 19.99Ω. Minimum resolution: 0.001Ω
    Admittance0.001 ms ~ 19.99ms. Minimum resolution:0.001 ms
    Power consumption< 20VA
    Rated frequency50 or 60HZ

    HLS-30G2 Standard Current Transformer with current generator


    Rated Primary Current (A)5, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 150, 160, 200, 250,300, 315, 400, 500, 600, 630, 750, 800, 1000, 1200, 1250, 1500, 1600, 2000, 2500, 3000, 3150....or More (optional)
    Rated Secondary Current5A, 1A
    Accuracy class0.05% or higher
    Rated secondary load0.2 ohm
    Frequency50HZ
    Operating Range1% - 120%
    Current source Capacity10kVA or more


    FY49 current transformer burden

    Rated Current5A or 1A (optional)
    Operating Range1%--120%
    Rated load (VA)

    CosФ = 0.8: 2.5, 3.75, 5, 6.25, 7.5, 10, 12.5, 15, 20, 25, 30, 40,

    50, 60 VA or more options

    CosФ = 1.0: 2.5, 3.75, 5, 6.25, 7.5, 10 VA or more options

    Rate Frequency50Hz
    Accuracy Class±3%

    FY95 Voltage transformer burden

    Rated voltage100V, 100/√3V or more options
    Operation Range20%--120%
    Rated load1.25VA, 2.5VA, 5VA, 10VA,20VA, 40VA, 80VA (Total load:158.75 VA) or more option
    Fundamental error±3%
    Power factorCOSФ=0.8
    Rated Frequency50Hz

    HJS-35G3 Standard Voltage Transformer with Voltage Generator

    Rated primary voltage6kV,10kV,15kV,22kV,35kV or more option
    Rated secondary voltage100V,100/√3V,110V,110/√3V, or more option
    Accuracy class0.05% or higher accuracy class
    Secondary capacity0.5VA or more option
    Power factorcosΦ=1.0
    Power frequency50HZ
    Range of operating voltage20%--120%
    Current transformer primary test cable

    2000A x 3m x 1set,1000A x 5m x 1set

    500A x 1.5m x 2set,250A x 1.5m x 2set,100A x 1.5m x 2set

    CT PT secondary test cableProvided