Sign In | Join Free | My himfr.com
Home > CT PT Test Equipment >

0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set

    Buy cheap 0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set from wholesalers
     
    Buy cheap 0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set from wholesalers
    • Buy cheap 0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set from wholesalers

    0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set

    Ask Lasest Price
    Brand Name : HNMC
    Model Number : HES-30
    Price : Negotiable
    Supply Ability : 5 sets per month
    Delivery Time : 30-45 days
    • Product Details
    • Company Profile

    0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set


    CT PT TEST Equipment System HES-30


    Technical Parameter


    HES-30 CT/PT Test Bench


    Input Voltage:AC 220V±10%, 50Hz, Single-Phase
    Input Current:AC 0-120A
    Rated Capacity:30kVA
    Output Voltage:AC 0-250V
    Output Current:AC 0-120A

    HES-1Bx Transformer Tester

    Measure item:Ratio errors & Phase errors of the CT and PT
    Rated current:5A, 1A
    Rated voltage:100V, 110V, 115V, 120V, 150V, 200V, 220V, 230V
    Multiplier:1/√3, 1/3, 1, 1.5, 2
    Accuracy class:±2%
    Operation range:(1%-120%).In, (20%-120%).Un
    Frequency:50Hz or 60Hz
    Ratio error range:±0.0001% ~ ±19.99% (3 ranges: 0.1999%, 1.999%, 19.99%).
    Minimum resolution:0.0001%.
    Phase error range:0.01' ~ ±900' (3 ranges: 9.00', 90.0', 900')
    Minimum resolution: 0.01'
    Impedance range:0.001Ω~ 19.99Ω.
    Minimum resolution: 0.001Ω.
    Admittance range:0.001 ms ~ 19.99 ms.
    Minimum resolution:0.001 ms.
    Alarm Function:Provided the sound & light alarm function when the polarity abnormal or ratio inconsistent.

    Input Load:

    - On Standard CT secondary side: ≈0.11Ω, COSφ≈1.0

    - On Test Object CT secondary side: ≈0.003Ω, COSφ≈1.0

    - On Standard PT secondary side: ≈0.05VA (100V)

    Communication Interface:Provided the RS232 serial PC communication interface
    Display model:LCD
    Power supply:AC 220V±10%, 60Hz
    Power consumption:< 20VA
    Product Type:Portable type.

    CT Burden FY47-49

    Rated Current:5A, 1A

    Power Factor

    and Rated Burden:

    In=5A:

    COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

    COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA

    (more option available)

    In=1A:

    COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

    COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA

    (more option available)

    Accuracy Class:±3%
    Operation Range:(1%-120%). In
    Frequency:50Hz or 60Hz
    Withstand Voltage:2kV/1min
    Insulation:Air
    Operating Model:Short-time (Used in CT Accuracy Testing System)
    Product Type:Portable type.

    High-current Test Cables of the CT

    Cables includes: 3000A(600mm2) x 3m x 2pcs, 1000A(200mm2) x 5m x 1pc

    500A(100mm2) x 3m x 2pcs, 250A(50mm2) x 3m x 2pcs


    HLB-50G1 Standard CT



    Rated Primary Current(A):

    5, 7.5, 10, 12.5, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 125, 150, 160, 200, 250, 300, 315, 350, 400, 450, 500, 600, 630, 700, 750, 800, 900, 1000, 1200, 1250, 1400, 1500, 1600, 1800, 2000, 2500, 3000, 3150, 3500, 4000, 4500, 5000A

    (more option available)

    Rated Secondary Current:5A, 1A
    Rated Current Ratio:5A~5000A/5A, 5A~5000A/1A (more option available)
    Accuracy Class:0.01S% (0.05%, 0.02%, 0.01% or better are available)
    Rated Secondary Burden:0.2Ω (Burden is 5VA at I2 = 5A, Burden is 0.2VA at I2 = 1A)
    Power Factor:COSΦ=1.0
    Operating Range:(1%-120%). In

    Connection Mode:

    Fixed connection terminals at Pri.current range is 5A-450A

    Pass-through connection with 2 turns at Pri.current range is 500A-900A

    Pass-through connection with 1 turn at Pri.current range is 1000A-5000A

    Frequency:50Hz or 60Hz
    Voltage Level:AC 600V
    Withstand Voltage:2000V 1min
    Insulating Medium:Air

    SLQ-30KVA Current Generator


    Input Voltage:AC 0-250V
    Output Current:AC 0-5000A
    Rated Capacity:30kVA
    Rated Input Current:AC 120A
    Frequency:50Hz or 60Hz
    Current Output Model:

    Fixed terminal at current is 50A, 200A, 500A

    Through-hole connection at current is 500A-5000A

    Products Shape:Stainless Steel Box
    Working condition:0 - 40ºC, RH ≤ 90%

    FY95-1 PT Burden

    Rated Voltage:100V, 100/√3V, 100/3V
    Power Factor:COSФ=0.8, COSФ=1.0
    Rated Burden (VA):

    1.25VA, 2.5VA, 5VA, 10VA, 20VA, 40VA, 50VA, 80VA, 100VA

    (more option available)

    Total Output Burden:308.75VA (more option available)
    Accuracy Class:±3%
    Operation Range:(20%-120%). Un
    Frequency:50Hz or 60Hz
    Withstand Voltage:2kV/1min
    Insulation:Air
    Operating Model:Short-time (Used in PT Accuracy Testing System)

    HJB-220G3 Standard PT

    Rated Primary Voltage:110/√3kV, 220/√3kV
    Rated Secondary Voltage:110V, 110/√3V, 100V, 100/√3V

    Rated Voltage Ratio:

    110/√3/0.11/√3kV, 110/√3/0.11kV, 110/√3/0.1/√3kV, 110/√3/0.1kV

    220/√3/0.11/√3kV, 220/√3/0.11kV, 220/√3/0.1/√3kV, 220/√3/0.1kV

    Accuracy Class:0.05% (100/√3V,110/√3V), 0.1% (100V,110V)
    Rated Secondary Burden:0.2VA(110V, 100V), 0.07VA(110/√3V, 100/√3V)
    Power Factor:COSΦ=1.0
    Operating Range:(20%-120%). Un
    Frequency:50Hz /60Hz
    Insulation:SF6 Gas


    HJC-80 Resonant High Voltage Source



    Product Application:

    The system is a voltage generator, and used for Capacitive PT accuracy testing with 110/√3kV and 220/√3kV voltage level
    Rated input voltage:AC 220V
    Rated output voltage:AC 0~200 kV
    Rated Capacity:200 kVar
    Max output current:AC 1.0 A
    Frequency:50Hz or 60Hz
    The capacitance of the object CVT:0.004uF ~0.02uF
    Operating Condition:Temperature: -10oC ~ +50 oC
    RH: up to 85% (max. 90%, non-condensing)

    LCB-10KVA/10KV Exciting Transformer

    Input Voltage:AC 0 - 250V, 50Hz
    Output Voltage:AC 0 - 10kV, 50Hz
    Output Current:AC 0-1A
    Rated Capacity:10kVA
    Insulation:Dry type
    Weight:~ 50 kg

    DKQ-40KVA/40KV Reactor

    Rated Capacity:40kVA/stage
    Rated Voltage:AC 40 kV/stage
    Rated Current:AC 1 A/stage
    Inductance Range:125H-500H/stage
    Insulation:Epoxy resin casting
    Weight:~ 60 kg/stage
    Quantity:5pcs

    Quality 0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Zhengzhou Great Electric Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)