CT PT TEST Equipment 3150A HES-10 CT&PT Accuracy Test System

    Buy cheap CT PT TEST Equipment 3150A HES-10 CT&PT Accuracy Test System from wholesalers
     
    Buy cheap CT PT TEST Equipment 3150A HES-10 CT&PT Accuracy Test System from wholesalers
    • Buy cheap CT PT TEST Equipment 3150A HES-10 CT&PT Accuracy Test System from wholesalers

    CT PT TEST Equipment 3150A HES-10 CT&PT Accuracy Test System

    Ask Lasest Price
    Brand Name : Metrum
    Model Number : HES-10
    Delivery Time : 20-25 Days
    • Product Details
    • Company Profile

    CT PT TEST Equipment 3150A HES-10 CT&PT Accuracy Test System

    HES-10 CT & PT Accuracy Testing System


    System Configuration

    • HES-10 CT&PT Test Bench
    • HES-1C Digital Transformer Tester
    • FY49 Current Transformer Burden (5A/1A optional)
    • HLS-30G2 Standard Current Transformer ( with Current Source)
    • FY95 Voltage Transformer Burden (100V,100/√3V or other ratio requirements are available)
    • HJS-35G2 Standard Voltage Transformer ( with Voltage Source)
    • Current Transformer Primary Testing Cable
    • CT & PT Secondary Testing Cable

    Main function description

    Product NameMain Function
    HES-1C Digital Transformer TesterMeasurement the Ratio error and phase error of the CT & PT
    FY49 Current Transformer BurdenThe secondary load of the CT
    HLS-30G2 Standard Current TransformerBenchmark of the CT and provide Current source
    FY95 Voltage Transformer BurdenThe secondary load of the PT
    HJS-35G2 Standard Voltage TransformerBenchmark of the PT and provide Voltage source
    HES-10 CT&PT Testing BenchTo provide testing power of the CT&PT, control function, CT demagnetization, etc.

    Product Technical Parameters


    HES-10 CT&PT Testing Bench

    Input VoltageAC 220V 50Hz or 60HZ Single-phase
    Output VoltageAC 0-250V
    Rated Capacity10kVA
    Regulation waycoarse adjustment & fine adjustment
    Adjustment wayManual adjustment
    Demagnetization Functionprovide “open-circuit demagnetization”, “closed-circuit demagnetization”, “Error measurement”
    Protection functionsprovide over current protection
    Equipment Can be installation and placedFY current transformer burden,FY voltage transformer burden,HES-1C Digital Transformer Tester,Other Control function etc.

    HES-1C Digital Transformer Tester

    Rate Current and Voltage

    5A, 1A, 110V, 110/√3V, 100/√3V, 1003V etc

    (Total 10 Rated Current and 15 Rated Voltage)

    Measuring range

    Ratio error range:

    ±0.0001% ~ ±19.99%(three positions: 0.1999%, 1.999%, 19.99%). Minimum resolution:0.0001%


    Phase error range:±0.01' ~ ±900'(three positions: 9.00',90.0',900'). Minimum resolution: 0.01'


    Impedance range:0.001Ω~ 19.99Ω.

    Minimum resolution: 0.001Ω


    Admittance:0.001 ms ~ 19.99 ms.

    Minimum resolution:0.001 ms

    Accuracy of Voltage and Current display

    Accuracy: ±1%

    Display range: 0-199,9%

    The secondary impedance of standard current transformer connected with Tester≤ 0.11Ω (cosφ = 1)
    The secondary impedance of tested current transformer connected with Tester≈ 0.003Ω (cosφ = 1)
    Loading of standard voltage transformer connected to the tester≈ 0
    Polarity display current and voltage< 30% of normal value
    Power consumption< 20VA
    Rate Frequency50Hz or 60HZ

    HLS-30G2 Standard Current Transformer (Include Current Source)


    Rated primary current(A)

    5,7.5,10,15,20,25,30,40,50,60,75,80,100,120,150,160,200,250,300,315,400,500,

    600,630,750,800,1000,1200,1250,1500,1600,2000,2500,3000,3150 or more optional

    Rated secondary current5A,1A
    Accuracy calss0.02% or higher accuracy class
    Rated secondary load0.2 ohm
    Frequency50Hz or 60HZ
    Operating Range1%--120%
    Capacity of the Current Source10kVA

    FY49 current transformer burden

    Rated Current5A or 1A (optional)
    Operating Range1%--120%
    Rated load (VA)

    cosФ = 0.8: 2.5, 3.75, 5, 6.25, 7.5, 10, 12.5, 15, 20, 25,30, 40, 50, 60 VA or more options

    cosФ = 1.0: 2.5, 3.75, 5, 6.25, 7.5, 10 VA or more options

    Rate Frequency50Hz or 60HZ
    Accuracy Class±3%

    FY95 Voltage transformer burden

    Rated voltage100V, 100/√3V or more optionals
    Operation Range20%--120%
    Rated load1.25VA, 2.5VA, 5VA, 10VA,20VA, 40VA, 80VA (Total load:158.75 VA) or more option
    Fundamental error±3%
    Power factorCOSФ=0.8
    Rate Frequency50Hz or 60Hz

    HJS-35G3 Standard Voltage Transformer (Include Voltage Source)

    Rated primary voltage6kV,10kV,15kV,22kV,35kV or more option
    Rated secondary voltage100V,100/√3V,110V,110/√3V, or more option
    Accuracy class0.05% or higher accuracy class
    Secondary capacity0.5VA or more option
    Power factorcosΦ=1.0
    Power frequency50Hz
    Range of operating voltage20%--120%

    Current transformer primary test cable

    Cable configuration:

    2000A x 3m x 1set,1000A x 5m x 1set

    500A x 1.5m x 2set,250A x 1.5m x 2set,100A x 1.5m x 2set