    Brand Name : HNMC
    Model Number : MCTB20B
    Payment Terms : L/C, T/T, Western Union
    Delivery Time : 4-8weeks
    Price : Negotiable
    Supply Ability : 20 Sets Per Month
    • Product Details
    • Company Profile

    450V Energy Meter Test Equipment , Lab Electric Meter Testing Equipment

    Single & Three Phase Meter Test Bench MCTB20B


    Technical Parameters

    Accuracy class0.05, 0.1 (optional)
    Output Voltage
    Range3*(1-450V) (P-N)
    Resolution0.01%
    THD<0.5%
    Accuracy & Stability0.05% or 0.02%
    Capacity≥ 800VA/phase (20 positions)
    Current output
    Range3* (1mA~ 120A), maximum can be 200A
    Resolution0.01%
    Distortion<0.5%
    Accuracy & Stability0.05% or 0.02%
    Capacity≥ 2500VA/phase (20 positions)
    Phase angle
    Adjustment range0° ~ 360°
    Resolution0.01°
    Frequency
    Range45-65HZ
    Resolution0.01HZ
    Other parameters
    Different value of each phase voltage and average value<0.5%
    Different value of each phase current and average value<1%
    Time base1 ~ 9999s
    Insulation between Voltage circuit vs. Current circuit, Between circuits vs. Earth≥ 5MΩ
    Power supply220V or 3×240V/415V±10%, 50/60Hz±10%
    Ambient conditions50C ~ 400C / up to 90% RH

    Features

    1) PWM (Pulse width modulation) technology

    2) Modular design allows customized configurations on hardware and software, customer-friendly

    3) Perform all basic tests like warm up, creep test, start test, basic errors, standard deviation and etc.

    4) Perform dial test with pulse counting & timing base with KWH value

    5) Mode of tests: Fully-automatic, or manual operation by manual control touch screen (MCU)

    6) Able to test all types of single phase and three phase mechanical meters, electronics meters, CT/PT

    operated meter, smart meter, closed-link meter, and etc..

    7) Error calculation display with reset buttons on each meter position

    8) Flexible Quick connector device (QCD) for convenient changeover from three phase meter

    to single phase meter

    9) Black mark search & capture for rotation disk

    10) Able to calibrate mechanical or electronics meters with different constant at the same time

    11) Powerful PC software for data analyzing, waveform playback and detailed report exportation

    12) Universal barcode input, and supports self-defined barcode

    13) Smart solutions for calibration with updatable software

    14) Temporary storage of data for later continued calibration

    15) Test Records save in database with MDB format or other required format

    16) Calibrate parameters including voltage, current of each phase, phase/phase difference,

    active/reactive/apparent power of each phase, total active/reactive/apparent power, total power factor,

    frequency, etc. with real time display of vector graph

    17) Harmonic test 2-40 times and analysis/display of harmonic

    18) With facilities to test apparent maximum demand recorded in meters and carry out the register test

    (the client should provide meter communication protocol for this function)

    19) Self-testing function for all phases power, total power stability, symmetry of 3 phase voltage and current

    20) PC software (communication by RS232) can realize MIS net interface connection function, can easily

    upgrade in the future if necessary

    21) Protection: current open-circuit, voltage short-circuit and malfunctions, Auto protection & auto restore

    22) Start & Stop button on power source

    23) Alarm lights installed on top of power source

    24) Can be independent set & output of each phase voltage & current, phase angle


    MTB Comprising:

    1) Three Phase Reference Standard Meter

    2) Three Phase Power Source

    3) Meter Mounting Racks

    4) MCU (manual control unit, touch screen operation)

    5) Scanning Heads

    6) Error Processing & Calculation & Indication System

    7) PC software, PC, printer, etc..


    Technical Specifications


    Three Phase Power Source

    Voltage Source

    Output Ranges: 3 x (0-380V) P-N

    Resolution: 0.01%

    Distortion: ≤ 0.5%

    Output Stability: ≤0.05% /3minutes

    Output power: more than 800VA per phase

    Setting accuracy of amplitude: 0.05%

    Current source:

    Output range: 3 x (1mA ~ 120A)

    Resolution: 0.01%

    Distortion: ≤ 0.5%

    Output Stability: 0.05%/3minutes

    Capacity: more than 2800VA per phase

    Setting accuracy of amplitude: 0.05%

    Output Phase angle:

    Adjustment range: 0° ~ 360°

    Resolution: 0.01°

    Setting accuracy: 0.05°

    Output frequency

    Adjustment range: 45Hz ~ 65Hz

    Resolution: 0.01Hz



    Other Features

    1) With short circuit and overload protection in voltage circuit

    2) With open circuit and overload protection in current circuit

    3) With display to show operating ranges and load points and indication of fault in case of abnormality

    4) With Provision ON/OFF current & voltage circuit

    5) All parts including voltage/current source and reference standard meter mounted in closed cabinet

    6) With ventilation and cooling fan for heat release

    7) With locks on front and back side doors for protection

    8) Front door with glass window to see display of touch screen and standard meter display

    9) Time base: 1 ~ 9999s

    10) Insulation between Voltage circuit vs. Current circuit, Between circuits vs. Earth: ≥ 5MΩ

    11) Power supply: 240V or 3×240V/415V±10%, 50/60Hz±10%

    12) Ambient conditions: Temperature 50C ~ 400C

    13) Relative humidity: up to 90%


    Three Phase Reference Meter


    1. Accuracy class: 0.05 or 0.02

    2. Measuring ranges & accuracy

    ParametersMeasuring rangeResolutionAccuracy
    Voltage phase-neutral1V ~ 576V6 valid digits0.05% or 0.02% (10-576V)
    Current3 x (1mA ~ 120A)

    6 valid digits

    0.05%or0.02%(10mA-120A)
    Active & Apparent Power / Energy40V ~ 576V / 10mA ~ 120A6 valid digits0.05% or 0.02%
    Reactive Power / Energy40V ~ 576V / 10mA ~ 120A6 valid digits0.1% or 0.05%
    Power factor (PF)-1.0 ~ +1.06 valid digits±0.0005
    Phase angle0 º ~ 360º6 valid digits0.02º (10-576V,10mA-120A, sine wave)
    Frequency40Hz ~ 70Hz6 valid digits0.005%

    3. Pulse output

    Energy impulse output

    Impulse frequency: FH=CH.P/3600(HZ); FL=FH/10000(HZ)

    Output level: TTL

    Table of Constant (for every inner voltage/current range)


    100A50A25A10A5A2.5A
    480V4x1058x1051.6x1064x1068x1061.6x107
    240V8x1051.6x1063.2x1068x1061.6x1073.2x107
    120V1.6 x1063.2x1066.4x1061.6x1073.2x1076.4x107
    60V3.2x 1066.4x1061.28x1073.2x1076.4x1071.28x108

    1A0.5A0.25A0.1A0.05A0.025A
    480V4x1078x1071.6x1084x1088x1081.6x109
    240V8x1071.6x1083.2x1088x1081.6x1093.2x109
    120V1.6x1083.2x1086.4x1081.6x1093.2x1096.4x109
    60V3.2x1086.4x1081.28x1093.2x1096.4x1091.28x1010

    4. Display (6 digits): voltage, current, active/reactive/apparent power, power factor, phase angle, frequency,

    waveform, vector diagram, harmonic analysis…etc

    5. Interface: RS-232 and/or RS-485

    6. Power Supply:240V±15%, 50Hz/60HZ±5%, power Consumption: ~ 20VA

    7. Working Environment

    Temperature: 50 C ~ 400 C; Relative Humidity: ≤ 90% Non-corrosive gases

    8. Weight: ~ 7.5kgs


    Meter Rack Configurations

    Three Phase Test Racks (20 positions, two racks, one row)

    Three Phase Test Rack

    Number of positions: 20 (6, 8,10, 12, 16, 32, 40 also available for option)

    Two emergency stop switch

    Each position consist of: 1 QCD 6 pins + 1 scanning head + 1 meter mounting

    + 1 RS/232/485+1 optical probe (DLMS meter reading)+ communication port + 1 error display (4.5 digits)

    +1 BNC pulse port + 1 RESET button + 1 Set of voltage cables+1 ICT

    Provision for calibrating standard meter against higher level standard

    One serial server

    Isolated Current Transformer (ICT) specification:

    Accuracy class: 0.01% (0.5C-1-0.5L)

    Current Ratio: 1:1 (1mA-120A)

    Current output: 3*(0.001-120)A (both primary and secondary)